REF · 02 / TRAITEMENT D'AIR12 models · ISO 8573-1

Refrigerant & adsorption dryers.

Drying compressed air is as critical as producing it. +3 °C dew point for 90 % of processes, −40 °C or −70 °C for pharma and electronics. ISO 8573-1 class 0 multi-stage filtration.

REF · 02-A

Refrigerant dryers — +3 °C.

The general industry standard. Compact plate exchanger, air or water cooling, condensate discharged by electronic drain. Covers 90 % of industrial needs.

  • Stable dew point +3 °C ±1
  • Plate exchanger (30 % footprint gain)
  • Air or water cooling
  • Electronic anti-loss drain
  • Range 1.2 to 25 m³/min (extensions possible)
ModelFlowPressureDew ptConsumptionL × W × H (mm)Weight
CZ-DRY-F101,2 m³/min7-16 bar+3 °C0,38 kW560 × 540 × 76050 kg
CZ-DRY-F303,6 m³/min7-16 bar+3 °C0,75 kW640 × 580 × 88085 kg
CZ-DRY-F606 m³/min7-16 bar+3 °C1,20 kW780 × 650 × 990130 kg
CZ-DRY-F10010 m³/min7-16 bar+3 °C1,85 kW950 × 720 × 1180195 kg
CZ-DRY-F15015 m³/min7-16 bar+3 °C2,60 kW1100 × 820 × 1390270 kg
CZ-DRY-F25025 m³/min7-16 bar+3 °C4,20 kW1280 × 950 × 1620400 kg
REF · 02-B

Adsorption dryers — −40 / −70 °C.

13X or 4A molecular sieve to reach extreme dew points. Heatless regeneration (15-18 % air purge) or micro-heat (4-7 % purge, 25-30 % savings).

  • Standard dew point −40 °C, optional −70 °C
  • Molecular sieve 13X (water) or 4A (water + CO₂)
  • Heatless or micro-heat regeneration
  • Adsorption cycle 5-10 min depending on model
  • Pharma, electronics, cleanroom compliant
ModelFlowPressureDew ptConsumptionL × W × H (mm)Weight
CZ-DRY-A101,2 m³/min7-10 bar−40 °CHeatless650 × 450 × 145095 kg
CZ-DRY-A303,6 m³/min7-10 bar−40 °CHeatless780 × 530 × 1680180 kg
CZ-DRY-A606 m³/min7-10 bar−40 °CHeatless950 × 620 × 1820285 kg
CZ-DRY-A10010 m³/min7-10 bar−40 °CHeatless1100 × 720 × 2050410 kg
CZ-DRY-A20020 m³/min7-10 bar−40 / −70 °CHeatless1300 × 850 × 2280720 kg
CZ-DRY-A40040 m³/min7-10 bar−40 / −70 °CMicro-heat1550 × 1000 × 25001150 kg
REF · 02-C

Multi-stage filtration.

5 filtration stages to reach ISO 8573-1 class 0. Selection per application: food 4-3-2, pharma 1-2-3, electronics 0-2-3 + activated carbon.

3 µm coalescing filter
Removes free water + particles > 3 µm · Standard industrial
1/5
1 µm coalescing filter
Removes oil + aerosols at 0.1 ppm residual · Pharma pre-filtration
2/5
0.01 µm high-efficiency filter
Removes submicron particles + bacteria · ISO 8573-1 Class 2
3/5
Activated carbon filter
Removes oil vapors + odors · < 0.003 ppm · ISO Class 1
4/5
0.01 µm sterile filter + UV
Removes bacteria + viruses · ISO 8573-1 Class 0 · Pharma / food
5/5
Sizing

Which dryer for your process?

Our technical team calculates the flow, required dew point and optimal pressure drop. Free pre-study including air quality audit.