Portable compressors for construction sites and quarries
Mobile, rugged, off-grid.
Construction sites, quarries and extraction sites require mobile, rugged compressors operating off-grid. They power jackhammers, drills, sandblasting and pneumatic demolition tools, in harsh environmental conditions: dust, vibrations, extreme temperatures, trailer transport.
What needs to be solved.
- 01Ensure complete energy autonomy via an integrated diesel engine compliant with CE Stage V emissions standards, with all-weather starting.
- 02Withstand field conditions (dust, shocks, road transport) thanks to a reinforced chassis and ISO 3744 compliant acoustic enclosure.
- 03Keep maintenance simple and accessible for site teams - direct access to filters, oil change, level checks.
Our technical answer.
On a site, the first criterion is not efficiency: it is starting, every morning, with no mains supply.

Portable diesel
37 to 429 kWFull autonomy from a diesel engine, a towable chassis, and maintenance done on the spot with simple tools.
46 catalogue models
Stationary diesel
295 to 447 kWThe same ruggedness in a fixed position, for site accommodation, a treatment plant or a long-running job.
7 catalogue models
High-pressure piston
2.2 to 45 kWWhen the tool needs a pressure far above the network: drilling, testing, high-pressure inflation.
38 catalogue modelsApplicable standards.
Compliances are verified case by case according to the selected model and audit scope. Complete documentation provided with each machine.
The classes usually required
A site needs no treated air for ordinary tools. Treatment becomes useful again as soon as a sensitive process is involved, or in site accommodation.
| Point of use | Particles | Water (dew point) | Oil |
|---|---|---|---|
| Site pneumatic tools | Classe 4 | Non traité | Classe 3 |
| Sensitive process, painting, spraying | Classe 3 | +3 °C (classe 4) | Classe 2 |
The questions we are asked
What flow should a construction site plan for?
Does site air need treating?
How do you keep up maintenance in harsh conditions?
Worth reading before deciding
How to size an air compressor: flow, pressure and storage
Sizing a compressor properly is not a matter of picking a power rating in kW: it means calculating the real flow, the right pressure and suitable storage. A 4-step method, with a worked example.
Predictive maintenance on air compressors: indicators, alerts, gains
Predictive maintenance eliminates 70 to 75% of breakdowns on average, according to the US Department of Energy, and extends component life. Here are the indicators to monitor and the alert thresholds.
Describe your process. We'll propose the right machine combination.
Reply from our technical team within 24 working hours. Free pre-study including sizing and budget estimate.